AN-1003 HOT-WIRE ANEMOMETRY SYSTEM |
|
|
|
The AN-1003 can measure fluid velocities from 0 and up to supersonic measurements. In addition to these inherent qualities of the basic AN-1003 system, there are 14 extra options which can be added to any number of channels. These expand the capabilities of the system, allowing it to make professional-standard measurements in different kinds of fluids. Another advantage of the AN-1003 is its modularity: channels can be removed or interchanged without disturbing other channels already calibrated for different experiments.
The AN-1003 is being used today at a large number of leading research institutes and universities throughout the world, where, for a number of years, it has proved its value as a reliable and accurate instrument, and has become a valuable research tool for scientists and engineers. Part of the AN-1003's success is due to its user-oriented design, making the system easy and straightforward to use by inexperienced students and professional researchers alike. We hope that you become part of this expanding group of satisfied AN-1003 users. Refer to the Technical Specification to find out about the outstanding capabilities and characteristics of the AN-1003. As a result of technological advances in design and production, A.A. Lab Systems can now offer you a complete AN-1003 anemometry system at a substantially lower price than in the past, making this highly reliable and accurate system highly affordable as well.
Easy operation. Low Noise - less than 2.2 nV/. Ultra Low Noise option - less than 400pV/. Intelligent modular design. CTA and CCA in a single channel (optional). Probe protection circuit. Soft-start circuit for delicate probes. High frequency response: DC-100kHz standard, DC-500kHz optional. Flexible: may be used with Hot-film and Hot-wire. Built-in Signal Conditioner : - Controllable Gain, - DC offset, adjustable to any value, - Noise Filter: Low Pass Filter with 12 cut-off frequencies. Built-in indicators aid user in balancing the Bridge. Built-in Square Wave/Pulse Generator. Fail-safe switches. Self-maintained, no expensive servicing required. 12-months Parts & Labor warranty.
Option 01 - ULTRA LOW NOISE INPUT AMPLIFIER - 400 PicoVolts / - less than 0.1mVrms output noise on 0-20kHz bandwidth. Option 03 - TEMP. COMPENSATION - discontinued, use Option 11 instead. Option 04 - FREQUENCY COMPENSATION - a tunable circuit for improving the frequency response up to 500kHz. Option 05 - BACKUP BATTERIES - provides operation without mains current for more than 2 hours. Built-in charger included. Option 06 - FILTER BANDS - other than specified. Please specify upper and lower cut-off frequencies in each band. Option 07 - GAIN OPTION - other than 1-20. please specify maximal gain required. Option 09 - DC OFFSET MEASUREMENT - on the test module with external BNC output. Option 10 - HIGH CURRENT POWER SUPPLY - capable of driving up to 10 probes in 1:1 bridge ratio as well as in x2 mode (up to 600mA per channel). Option 11 - CCA (Constant Current Anemometer) in addition to CTA mode, with 31 fixed current levels and a variable current of 0.3-30mA. Option 12 - HIGH PERFORMANCE SIGNAL CONDITIONER - gain of 1-100 (1-200 optional) with 1-10 variable control and a gain multiplier of x1, x2, x5, x10. High accuracy DC offset (2ppm/°C stability) with a variable control of 0-2V + fixed steps of 0,2,4,6,8 Volts. DC-off function. Use for low velocities and low turbulence levels. Option 13 - EXTERNAL POWER SUPPLY REMOVAL KIT - for removing the power supply to an external rack for ultra high Noise Immunity. Option 14 - AUTO-ZERO DC OFFSET - for automatic reduction of DC offset (use for Velocity profiles or near wall). Control signals are TTL compatible (zero + read DC offset). Option 15 - 5m RG-58 COAXIAL PROBE CABLE. Notes: 1. Probe protection and soft start circuits are standard on all channels. 2. All mainframes are built for 115/220Vac 50/60 Hz operation.
|