Uscita in frequenza calibrata (TTL)
Mezzo della sonda di temperatura esposto
Memoria di identificazione
Specifiche
Flow ranges and process connections see table
Output signal flow Frequency 2 kHz (TTL) max
Metrological properties Flow (at viscosity 1 mm2/s, app.) Repeatability ± 0.025 % of reading Response time 2 ms app.
Metrological properties Temperature Isolated thermocouple T-type (DIN EN 60584 class 2)
Supply voltage 9 to 32 V DC reverse polarity protected
Power consumption ≤ 8 mA
Material wetted parts stainless steel and ceramic
Operating temperature range Process media −40 °C to +150 °C Ambient −40 °C to +125 °C
Process pressure at +20°C 25 bar max., others on request
Electrical connection high temperature shielded cable, length 50 cm with push-pull connector size 0
Degree of protection IP67
EMC EN 55011 EN 61000-4-2 to EN 61000-4-6
Calibration certificate included
Accessories high temperature shielded cable, length 5 m to connect VCT turbine meter with VCA or VCA-T flow computer, other accessories see separate datasheet